Vanguard L

Vanguard L boilers are designed with a large combustion chamber positioned in the lower part of the heat exchanger, ensuring maximum heat transfer efficiency (up to 92.5% nett).

With an increased number of flue ways positioned in the hottest area of the heat exchanger and constructed from thicker steel, the Vanguard L range is capable of an impressive output to size ratio.

This boiler range is suitable for combined indirect pumped domestic hot water and central heating systems, independent indirect pumped domestic hot water or central heating systems.

Fully pumped systems may be open vented or sealed.

Efficiency

Models in this range operate between 83 and 87% energy efficiency

Features

  • 18 models with outputs 130 to 3500 kW
  • Fuel flexibility – Natural gas, oil or dual fuel
  • High efficiency 91% net (82% gross)
  • 3 pass heat exchanger
  • Compact size
  • Comprehensive control
  • 6 bar pressure standard
  • Ease of service and maintenance
  • Stylish appearance

Specification

  • General Data (130-870 kW)
  • General Data (970-3500 kW)
Model 170240290340420510630760870
OutputkW170240290340420510630760870
Heightmm127212721372137215421542154216221622
Widthmm82082086086089089089011221122
Depthmm121414741411154116061801211319892184
Flow/Return ConnectionsDN flange65658080100100100125125
Flue Sizemm200200250250250250250350350
Maximum Working Pressurebar6
Water ContentL190251264298398462565671753
Dry Weight (Approx)kg435510588629769919104713411447
Boiler Clearances (mm)FrontSame as boiler length
Back500
Side (non hinge)100
Right200 + burner length
Seasonal Efficiency(gas) %83.0482.9883.0283.0383.0983.0283.2283.4083.34
(oil) %86.4086.3086.3086.4086.4086.3086.5086.7086.70
Model 97011001320157018502200265030003500
OutputkW97011001320157018502200265030003500
Heightmm162216221622173217321892189220802340
Widthmm112213521352146214621622162216701920
Depthmm237923462686278131513225354538353879
Flow/Return ConnectionsDN flange125150150175175200200200200
Flue Sizemm350400400450450520520570620
Maximum Working Pressurebar6
Water ContentL83610401242141816172086232425534862
Dry Weight (Approx)kg155318212030278032804145446551106700
Boiler Clearances (mm)FrontSame as boiler length
Back500
Side (non hinge)100
Right200 + burner length
Seasonal Efficiency(gas) %83.4283.5683.4083.4783.4783.7383.8283.0283.15
(oil) %86.8086.9086.7086.8086.8087.1086.2086.3086.50